Use this 16A B-curve circuit breaker (MCB) to protect a circuit that needs a little more power than a small lighting circuit. The Schrack BMS4 disconnects both conductors as soon as the current rises too high or a short circuit occurs.

What is a 16 A B-curve MCB for?

On a 1.5 mm² conductor, 16 A is the highest rating that AREI (the Belgian electrical installation regulations) permits in homes. A B curve is mainly chosen for:

  • a long circuit, where the short-circuit current at the end of the cable remains low
  • heating appliances without inrush current, such as an electric radiator or heated towel rail
  • an appliance for which the manufacturer specifies a B16

Why a B curve?

A B-curve MCB trips magnetically at 3 to 5 times the rated current, so at 16 A from as little as 48 to 80 A. This means a smaller short-circuit current is enough to make it trip quickly. The downside: motors and large amounts of LED lighting with a high inrush current can cause nuisance tripping; a C-curve MCB is a better fit there.

Installation and connection

This MCB takes up two modules on the DIN rail. Because the terminals are open on both sides, a busbar can run along the top as well as the bottom. The terminals accept conductors from 1 to 25 mm².

Good to know

This MCB is designed for alternating current; the DC side of a solar panel system requires separate DC protection. Leave the installation to a qualified electrician; once the work is complete, a mandatory inspection by an approved inspection body follows.

Product codeBM418216 (Schrack BMS4 B 16/2)
EAN9004840394337
Rated current16 A
Tripping curveB
Poles2P, both poles protected
Breaking capacity4.5 kA (EN 60898-1), 6 kA (EN 60947-2)
Rated voltage230/400 V AC, 50/60 Hz
Width2 modules (approx. 35 mm)
Terminal capacity1 to 25 mm²
Max. back-up fuse80 A gG
Degree of protectionIP20, IP40 with cover
Ambient temperature-5 °C to +40 °C (calibrated at 30 °C)
StandardsEN 60898-1, EN 60947-2
Reference9004840394337
Category Circuit breakers and RCDs
Merk Schrack
Weight 0.24 kg

Shipping with GLS

  • We ship with GLS to your address in Belgium for €7.95; shipping is free when you spend €65 or more on standard items. To the Netherlands: €11.95, free from €75.
  • Items in stock are dispatched within 2 working days; GLS usually delivers the next working day. You will receive an email with the tracking code.
  • Collection in Tongeren-Borgloon is free: choose "Collection" at checkout and come by once you have received our message that your order is ready.
  • 14-day cooling-off period for consumers: return the item or bring it back to us. You may examine it as you would in a shop; if it has been used beyond that, we deduct the diminished value.

All about delivery & returns →

Your cart
Loading…