Schrack RCD 2P 300 mA 40A

Schrack BCF6 300mA residual current device (RCD), 2-pole, 40 A, Type A, for use as the main RCD at the origin of a two-conductor installation: single-phase or on 3×230 V.

52.07 € 52.07 €

  • Merk
✓ Free shipping from €65 (BE) and €75 (NL) on standard items ✓ 14-day cooling-off period · terms and conditions
Merk: Schrack

In a home, this 300 mA residual current device (RCD) usually serves as the general or main RCD, at the origin of the installation, immediately after the meter. It monitors all circuits together for leakage currents and switches everything off in the event of an insulation fault. This limits the risk of fire and of a dangerous touch voltage.

What is a 300 mA main RCD for?

AREI (the Belgian electrical installation regulations) requires an RCD of no more than 300 mA at the origin of every domestic installation. The 2-pole version suits a two-conductor supply: phase and neutral, or two phases in a 3×230 V network. Downstream, the bathroom, washing machine, tumble dryer and dishwasher also get their own 30 mA RCD.

Benefits

  • Type A: also detects pulsating DC faults from appliances with electronics
  • short-circuit withstand up to 6 kA with a back-up fuse of max. 63 A gG
  • top or bottom feed, mounting in any orientation
  • IP40 once installed in the consumer unit

Installation and connection

As the main RCD, it goes at the front of the row, followed by the circuit breakers and the 30 mA RCDs. Each terminal combines a cage terminal and a lift terminal, so a busbar and a cable fit together. The tightening torque for the PZ2 screws is 2 to 2.4 Nm.

Good to know

The 40 A rating must suit your supply and the upstream protection; your electrician will check this. Leave the installation to a qualified electrician. The mandatory inspection by an approved inspection body then follows: among other things, the inspector measures the earth resistance and usually seals the main RCD.

Product codeBC654230 (Schrack BCF6 40/2/03-A)
EAN9004840394054
Rated current40 A
Rated residual operating current (IΔn)300 mA
TypeA (AC and pulsating DC), no time delay
Poles2P
Rated voltage230 V AC, 50/60 Hz
Short-circuit withstand6 kA with back-up fuse of max. 63 A gG
Tripping timemax. 300 ms at 300 mA, max. 40 ms at 1.5 A
Width2 modules (35 mm)
Terminal capacity1 to 35 mm² solid, 2 × 16 mm² flexible
Power loss5.4 W
Operating temperature-25 °C to +40 °C
StandardsEN 61008-1, EN 61008-2-1
Reference9004840394054
Category Circuit breakers and RCDs
Merk Schrack
Weight 0.22 kg

Shipping with GLS

  • We ship with GLS to your address in Belgium for €7.95; shipping is free when you spend €65 or more on standard items. To the Netherlands: €11.95, free from €75.
  • Items in stock are dispatched within 2 working days; GLS usually delivers the next working day. You will receive an email with the tracking code.
  • Collection in Tongeren-Borgloon is free: choose "Collection" at checkout and come by once you have received our message that your order is ready.
  • 14-day cooling-off period for consumers: return the item or bring it back to us. You may examine it as you would in a shop; if it has been used beyond that, we deduct the diminished value.

All about delivery & returns →

Your cart
Loading…