Schrack RCD 4P 300 mA 40A

Schrack BCF6 4-pole 300mA residual current device (RCD), 40 A, Type A, for use as the main RCD on a three-phase supply with neutral (3N×400 V).

59.50 € 59.50 €

  • Merk
✓ Free shipping from €65 (BE) and €75 (NL) on standard items ✓ 14-day cooling-off period · terms and conditions
Merk: Schrack

If you have a three-phase supply, this 300 mA 4-pole residual current device (RCD) is the usual choice as the main RCD. It sits at the origin of the installation and monitors the three phases and the neutral for leakage currents. If an insulation fault occurs anywhere in the house, it switches off the entire installation.

What is a 4-pole main RCD used for?

Under AREI (the Belgian electrical installation regulations), every domestic installation starts with an RCD of no more than 300 mA. An RCD only works if all live conductors pass through it; with a 3N×400 V supply, there are four. Next come the circuit breakers and, for the bathroom, washing machine, tumble dryer and dishwasher, the additional 30 mA RCDs.

Benefits

  • Type A, so also sensitive to pulsating DC faults
  • tripping independent of the mains voltage
  • 6 kA short-circuit withstand with a back-up fuse up to 63 A gG
  • red or green contact position indicator

Installation and connection

Install it immediately after the meter, at the origin of the installation. The device takes up 4 modules on the DIN rail, and the supply can come in at either the top or the bottom. Once installed in a consumer unit, it has a degree of protection of IP40.

Good to know

Check with your electrician whether 40 A per phase suits your supply capacity. Schrack recommends pressing the test button monthly; this test does not replace a measurement of the earthing. Have the device installed by a qualified electrician, after which an approved inspection body must inspect the installation.

Product codeBC654130 (Schrack BCF6 40/4/03-A)
EAN9004840394184
Rated current40 A
Rated residual operating current (IΔn)300 mA
TypeA (AC and pulsating DC), no time delay
Poles4P (3P+N)
Rated voltage230/400 V AC, 50/60 Hz
Short-circuit withstand6 kA with back-up fuse of max. 63 A gG
Tripping timemax. 300 ms at 300 mA, max. 40 ms at 1.5 A
Width4 modules (70 mm)
Terminal capacity1 to 35 mm² solid, 2 × 16 mm² flexible
Power loss8.4 W
Operating temperature-25 °C to +40 °C
StandardsEN 61008-1, EN 61008-2-1
Reference9004840394184
Category Circuit breakers and RCDs
Merk Schrack
Weight 0.32 kg

Shipping with GLS

  • We ship with GLS to your address in Belgium for €7.95; shipping is free when you spend €65 or more on standard items. To the Netherlands: €11.95, free from €75.
  • Items in stock are dispatched within 2 working days; GLS usually delivers the next working day. You will receive an email with the tracking code.
  • Collection in Tongeren-Borgloon is free: choose "Collection" at checkout and come by once you have received our message that your order is ready.
  • 14-day cooling-off period for consumers: return the item or bring it back to us. You may examine it as you would in a shop; if it has been used beyond that, we deduct the diminished value.

All about delivery & returns →